1. Home
  2. >
  3. Gas Detection
  4. >
  5. Gas Detector Tube
  6. >
  7. KwikDraw Speciality Tubes

KwikDraw Dosimeter Tubes

KwikDraw Dosimeter Tubes are Time Weighted Average (TWA) tubes specifically designed to measure exposure to VOC’s at the workplace.

KwikDraw Smoke Tubes

Kwikdraw Smoke Tubes indicate the airflow in a room and can also be used to find leakages in pipelines.

KwikDraw Charcoal/Sorbent Tubes

Charcoal tubes and Silica Gel tubes are sorbent tubes specifically designed to monitor personal exposure to organic vapors and aerosols.

KwikDraw PID Pre-Filter Tubes

KwikDraw PID Pre-Filter Tubes are used for the selective determination of Benzene/Butadiene in air containing a mixture of volatile organic compounds

Breathing Air Quality Monitoring Kits

Uniphos Breathing Air Quality Monitoring Kits are the answer for on-the-spot results to assure your workers are receiving air which is not contaminated with high levels of water, oil, CO or CO2

Kwikdraw Fire Brigade Kits

Kwikdraw fire brigade kits help quickly identify unknown hazardous gases generated during a fire accident.

Action Sets and Tubes

Action sets and tubes are tailor made to quickly evaluate potential dangers resulting from accidents.

KwikDraw ETW Tubes

ETW short for ‘Einsatztoleranzwert’ in German means operational tolerance value according to the German guideline VFDB 10/01 [03/03].

CWA Tubes

Chemical Warfare Tubes enables first responders to deal with unknown chemical warfare agents.

Industrial Sets

Industry Action Sets are sets of gas detector tubes, designed for specific applications.

Hazmat Kits

Hazmat kits are portable kits designed to aid in the initial assessment of potentially hazardous situations.

KwikDraw Dosimeter Tubes

KwikDraw Dosimeter tubes are custom made to measure Time Weighted Average (TWA) gas concentrations over longer durations. The gas enters the dosimeter tube by the principle of natural diffusion. The sensing chemical in the dosimeter tube changes color if the target gas is present. The length of discoloration is proportional to the concentration of gas in ppm.hrs present in the area. This length of stain can be easily read against pre calibrated measurement scale printed on the tube.KwikDraw dosimeter tubes are convenient, easy to use, pre calibrated tubes that come with a safe tube holder. Customers just have to break the tube and place it in the tube holder. After completion of the measurement period, remove the tube from the tube holder and read the gas concentration directly from the printed scale on the tube.

KwikDraw Dosimeter Tubes
Substance Ordering Code Data Sheet MSDS
Mini CO dosimeter tube D5091738
PDF

PDF

Smoke Tubes

KwikDraw Smoke tubes are tailor made to test the performance of ventilation systems in buildings, leak detection around doors and windows, etc. These tubes consist of ampoules, which when crushed and air allowed to pass through, produces a visible aerosol plume of white smoke.

Two variants of KwikDraw Smoke Tubes are available:
Non-Corrosive Smoke Tubes: These tubes are used to produce non-corrosive gas and are used where human presence is high. These tubes are used to identify air flow patterns and leaks in mine shafts and tunnels, commercial buildings, and industrial processing plants.

Corrosive Smoke Tubes: These tubes are used to produce corrosive gas and are used where human breathing or presence is very low. These tubes are used mainly for ventilation checks, testing the performance of fume hoods, and breathing apparatus fit testing.

Smoke Tubes
Substance Ordering Code Data Sheet MSDS
ST Smoke tube, Pkg. of 10 D5019701
PDF

PDF
Smoke Generator D5019702
PDF
ST Ventilation Smoke Tube, Pkg. of 10 D5019704
PDF

PDF
ST Smoke Cartridge, Pkg. of 10 D6009000
PDF
ST Smoke tube non-corrosive, Pkg. of 12 D5019708
PDF

PDF
ST Smoke tube non-corrosive, 6 pcs. + pump D5019709
PDF

PDF
Aspirator bulb D5019710
Bulb for smoke generator tubes D5019903

KwikDraw Charcoal/Sorbent Tubes

Activated Charcoal and silica gel sorbent tubes are suitable for active sampling of organic gases and vapors such as amines, alcohols, ketones, esters, etc. in the ambient air when used in combination with a suitable pump. They consist of sealed glass tubes filled with accurately weighed, high quality sorbents.

KwikDraw Charcoal/Sorbent Tubes
Substance Ordering Code Data Sheet MSDS
CT Charcoal tube B, Pkg of 10 D5086740
PDF

PDF
CT Charcoal tube G, Pkg of 10 D5086741
PDF
CT Silica tube B / BIA, Pkg of 10 D5086742
PDF
CT Silica tube G, Pkg of 10 D5086743
PDF
CT NIOSH charcoal tube, Pkg of 10 D6103730
CT Coconut coal, BIA, Pkg of 10 D6103740
PDF
CT NIOSH charcoal tube, Pkg of 50 D6103930
CT Coconut coal, BIA, Pkg of 180 D6103940
PDF
CT Silica tube B, Pkg of 180 D5086942
PDF
CT Charcoal tube G, Pkg of 180 D5086941
CT Charcoal tube B, Pkg of 180 D5086940
PDF
Charcoal Filter Tube ADS, Pkg of 10 D5085832
PDF
CT Silica Tube B / BIA, Pkg of 10 D5086742
PDF

 

PID Pre-Filter Tubes

KwikDraw PID Pre-Filter tubes are used to filter volatile organic compounds from an air sample and only allow Benzene/ Butadiene to pass through for a Benzene/ Butadiene specific measurement. These tubes are generally used in conjunction with a PID based gas monitor allowing Benzene/ Butadiene specific measurements. They are available in a variety of specifications enabling them to be used with most of the popular PID instruments available in the market.

PID Pre-Filter Tubes
Substance Standard Range Ordering Code Data Sheet MSDS
PID Pre-Filter Tube Benzene-0.05 0.05–200 D7095863
PDF

PDF
Pre-filter tube for butadiene 0.1–200 D7095869
PDF

PDF
PID VOC Zeroing Tube D7086765
PDF

PDF

Breathing Air Quality Monitoring Kits

Most of us take pure breathing air for granted, but for workers in various industries, it’s a matter of life or death. Uniphos understands the needs and is committed to working with industries that require equipment like our Breathing Air Quality Monitoring Kits, which are used to monitor the purity of breathing air as supplied directly from air compressors, breathing air cylinders or medium pressure air lines supplying air for airline applications and pneumatic machinery. The Airtester can indicate quickly and quantitatively the concentration of water vapor, oil, carbon dioxide, carbon monoxide, and nitrous fumes.

  • Air Tester HP (High Pressure) Kit – The HP version is used directly from 2216 or 4500 psi SCBA cylinders or high-pressure compressors using the DIN 300 to SCBA adapter suppled with each kit. Multi-Port configuration enables the user to test up to four tubes simultaneously.
  • Air Tester MP (Medium Pressure) Kit – The Airtester MP tests with one tube at a time and is ideal for plant supplied systems where the typical in-plant air lines operate at 80 to 120 psi.
Breathing Air Quality Monitoring Kits
Substance Ordering Code Data Sheet
Air Tester HP D3188702
PDF
Air Tester MP D5185710
PDF
Action kit [Gas-Tester II H] D5146803
SF6 Sampling Kit D5185700
Airtester Adapter R 5/8″ 200bar D4071017
Airtester Adapter R 5/8″ 300bar D4073018

Kwikdraw Fire Brigade Kits

During fire accidents, some chemicals such as fluorine gas, perchlorate salts like ammonium perchlorate or chlorine trifluoride, act as oxidizers, sometimes more powerful ones than oxygen itself. A fire based on a reaction with these oxidizers can be very difficult to put out until the oxidizer is exhausted. Some of the gases like chlorine and nitrogen dioxide causes an explosion when present along with a combustible gas.

It thus becomes necessary to analyse the environment where the fire had occurred for various organic, inorganic & toxic gases. KwikDraw understands these needs and is committed to work with the fire brigade industry to provide a solution – the KwikDraw Fire brigade Kit, which not only helps determine the cause of fire, but also helps to identify the resulting hazardous gases generated during the fire. The various such Kits available are:

  • KwikDraw Fire Kit I: Consisting of 26 KwikDraw gas detector tubes, air sampling pump, sampling hose and airflow indicator kit.
  • KwikDraw Fire Kit II: Consisting of 40 KwikDraw gas detector tubes, air sampling pump, sampling hose and airflow indicator kit.
Kwikdraw Fire Brigade Kits
Substance Description Ordering Code Data Sheet
KwikDraw Fire Brigade Kit I (26 tubes) Consisting of 26 colorimetric detector tubes, Gas Tester IIH, sampling hose and airflow indicator kit. 10013357
KwikDraw Fire Brigade Kit II (40 tubes) Consisting of 40 colorimetric detector tubes, Gas Tester IIH, sampling hose and airflow indicator kit. 10013358

Action Sets and Tubes

A quick assessment of the possible threat which might occur from fire, accidents, and other disasters is achieved with the KwikDraw Action Sets and Tubes. Only two warning marks are printed on the Action Tubes to ensure a rapid and simple reading.

Action Sets and Tubes
Substance Ordering Code Data Sheet MSDS
DT Set “Action Set” 10013397
DT Action Detector Tubes Assortment 1 D5085752
DT Action Detector Tubes Assortment 2 D5085753
DT NH3-A, Pkg of 10 D5085755
PDF

PDF
DT HCN-A, Pkg of 10 D5085756
PDF

PDF
DT Cl2-A, Pkg of 10 D5085757
PDF

PDF
DT CO2-A, Pkg of 10 D5085758
PDF

PDF
DT CO-A, Pkg of 10 D5085759
PDF

PDF
DT Nitr.-A, Pack of 10 D5085760
PDF

PDF
DT Phosgene-A, Pkg of 10 D5085761
PDF

PDF
DT HCl-A, Pkg of 10 D5085762
PDF

PDF
DT SO2-A, Pkg of 10 D5085763
PDF

PDF
DT H2S-A, Pkg of 10 D5085764
PDF

PDF
DT Gasoline-A, Pkg of 10 D5085769
PDF

PDF
DT Aromatics-A, Pkg of 10 D5085770
PDF
DT CKW-A, Pkg of 10 D5085771
PDF

PDF
DT Dichloromethane-A, Pack of 10 D5085772
PDF

PDF
DT Alcohols-A, Pkg of 10 D5085773
PDF

PDF

KwikDraw ETW Tubes

Kwikdraw ETW tubes are special gas detector tubes that indicate if working personnel when using the respiratory protection devices are exposed to gas concentrations above the ETW levels for more than 4 hours. ETW tubes are available for more than 30 substances.

KwikDraw ETW Tubes
Substance Ordering Code Data Sheet MSDS
DT Acrilonitrile 0.5 ETW, Pkg of 5 10016607
PDF
DT Acrolein-0.1 ETW, Pkg of 10 10017881
PDF
DT Cl-0.2 ETW, Pkg of 10 D5092801
PDF
DT SO2-1 ETW, Pkg of 10 D5092803
PDF
DT NO2-0.5 ETW, Pkg of 10 D5092805
PDF
DT Benzene-5 ETW, Pkg of 10 D5092816
PDF
DT CO2-0.1% ETW, Pkg of 10 D5092817
PDF
DT CO-10 ETW, Pkg of 10 D5092821
PDF
DT Hydrocyanic acid-2 ETW, Pkg of 10 D5092824
PDF
DT H2S-1 ETW, Pkg of 10 D5092826
PDF
DT Toluene-5 ETW, Pkg of 10 D5092828
PDF
DT PH3-0.05 ETW, Pkg of 10 D5092829
PDF
DT CS2 ETW, Pkg of 10 D5092834
PDF
DT VC-1 ETW, Pkg of 10 D5092837
PDF
DT Tri-5 ETW, Pkg of 10 D5092842
PDF
DT NH3-2 ETW, Pkg of 10 D5092845
PDF
DT Hydrochloric acid ETW, Pkg of 10 D5092846
PDF
DT Phosgene-0.1 ETW, Pkg of 10 D5092854
PDF
DT Per-5 ETW, Pkg of 10 D5092865
DT Chlorobenzene ETW, Pkg of 10 D5093811
PDF
DT Formaldehyde ETW, Pkg of 10 D5093813
PDF
DT Ethanol-100 ETW, Pkg of 10 D5093818
PDF
DT Styrene-10 ETW, Pkg of 10 D5093819
PDF
DT Acetic acid-1 ETW, Pkg of 10 D5093821
PDF
DT Acetone-100 ETW, Pkg of 10 D5093829
PDF
DT HF-1 ETW, Pkg of 10 D5093830
PDF
DT Hexane-20 ETW, Pkg of 10 D5093832
PDF
DT 1,1,1-Trichloroethane, Pkg of 10 D5093834
PDF
DT Phenol-1 ETW, Pkg of 10 D5093838
PDF
DT Hydrazine-0.1 ETW, Pkg of 10 D5093861
PDF
DT Methanol ETW, Pkg of 10 D5094818
PDF

CWA Tubes

CWA Tubes are detector tubes used to identify chemical warfare agents like Phosphoric Acid ester, cyanogen chloride, Lewisite, etc. These tubes help in the rapid identification of chemical warfare agents during an accident, providing a valuable tool to first responders.

CWA Tubes
Substance Ordering Code Data Sheet MSDS
Phosphoric acid ester D5086880
PDF

PDF
HD, HN D5086881
PDF

PDF
HD D5086882
PDF

PDF
Lewisit D5086883
PDF

PDF
Cyanogen Chloride D5086884
PDF

PDF
Agent BZ D5086885

Industrial Sets

Industrial sets are designed for the rapid detection of 4 to 5 gases/ vapors. Sets comprise of tubes with two scale marks for semi-quantitative assessments using one tube at a time. On offer are Industrial Sets for specific industries like Agricultural, Pharmaceutical, Petroleum, Mining, Pulp and Paper, Synthetics Manufacturing, and Semiconductor.

Industrial Sets
Substance Ordering Code Data Sheet
DT Set “Action Set” 10013397
DT Set Indoor Air Set D5086848
DT Set Tubes according “VFDB” 10013355
DT Set Tubes according “GW-G” 10013356
DT Set Trainer tubes D5019703
DT Set Agric., Pkg of 12 D5086870
DT Set Pharma, Pkg of 12 D5086871
DT Set Pulp & Paper Set, Pkg of 12 D5086872
DT Set Mining Set, Pkg of 12 D5086873
DT Set Synthetics Set, Pkg of 12 D5086874
DT Set Petroleum Set, Pkg of 12 D5086875
DT Set Semiconductor Set I D5086876
DT Set Semiconductor Set II D5086877
DT Set Semiconductor Set III D5086878
DT Set Semiconductor Set IV D5086879

Hazmat Kits

Hazmat kits are also known as first/ fast responder kits. It is tailor made to determine the unknown contaminants in air during a hazardous incident or in an industrial setting. It consists of a variety of gas detection tubes to help emergency response, fire, and Hazmat teams quickly and easily classify unknown chemical gases and vapours that might be present in the atmosphere.