UV-VIS COD-TSS Probe with Controller
Operating on the principle of absorption spectroscopic technique to measure COD, BOD & TSS in Industrial wastewater, surface water, etc., the probe is equipped with a solenoid valve which is capable of auto purging/ cleaning the sensor. The Light source and UV detector present in the instrument provide an accurate measurement of COD, BOD, & TSS in wastewater.
Equipped with a next generation touchscreen HMI controller for display and programming the unit, the probe provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output. The analyser is also programmed to display BOD value of known matrix
- Effluent Treatment Plant
- Surface water Monitoring
- Industrial Process Waste-Water Monitoring
- Automatic cleaning of probe with high-pressure compressed air provides higher reliability than the mechanical blade
- No reagents
- Low operating cost
- No secondary pollution
- Fast response, suitable for online real time measurements
- No chloride ion interference
- Detection Principle: Optical absorption (COD: 254nm & TSS: 860nm)
- Range: COD: 0-400mg/L
- BOD: 0-400mg/L
- TSS: 0-100 NTU (also available in mg/l)
- Accuracy: ± 10% of the reading
- Zero Drift: < 1% FS
- Response Time: 10 seconds
- Calibration: Calibration with KHP for COD and Formazine standard for TSS.
- Power Requirement: Probe – 24VDC
- Controller – 230V AC/50 Hz
- Data Communication: RS 485(MODBUS-RTU Protocol) & 4-20 mA
- Max. Load Resistance: 500Ω on 4-20mA O/P
- Display: 4.3” TFT with touchscreen
- Body Material: SS 316
- Operating Temp: 5-45o Celsius
- Dimensions: Probe – Diameter: 90mm, Height: 320mm
- Controller – H=260mm, L=160mm, B=90mm
- Weight: Probe: 2.5kg Approx.
- Controller: 3.5Kg Approx